Technical Data Sheets
HY-OPTIMA™ 1700
HY-OPTIMA™ 1700AS
HY-OPTIMA™ 1720
HY-OPTIMA™ 1730
HY-OPTIMA™ 1740
Customer Application
Downloadable Brochure
Product Manual
Other Sensor Products
HY-ALERTA™ 500
HY-ALERTA™ 600
HY-ALERTA™ 1600
HY-ALERTA™ 2600
HY-OPTIMA™ 700
HY-OPTIMA™ 1700 Intrinsically Safe Process Hydrogen Monitor
*Pictures shown may include future optional equipment
H2scan’s HY-OPTIMATM 1700 in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA™ 1700 is an intrinsically safe device that incorporates our patented solid-state sensor and is configured to operate in background gas streams with up to 95% relative humidity and temperatures up to100ºC. The HY-OPTIMA™ 1700 is ideal for process gas streams containing virtually no contaminants and where real time continuous measurements of hydrogen can increase process plant efficiencies, improve diagnostics and enhance maintenance management translating into higher profitability.
Performance
Hydrogen Sensitivity Range:
0.5% to 100% hydrogen by volume at 1 ATM
Response Time: T90 < 30 sec
Ingress Protection: IP64 capable
Recommended Verification Interval: 90 days
Product Life Expectancy: 10 years
Accuracy(*):
± 0.3% absolute for 0.5 to 10% H2
± 1.0% absolute for 10 to 100% H2
Drift/week:
± 0.2% absolute for 0.5 to 10% H2
± 0.4% absolute for 10 to 100% H2
Repeatability:
± 0.2% absolute for 0.5 to 10% H2
± 0.4% absolute for 10 to 100% H2
Linearity:
± 0.2% absolute for 0.5-10% H2
± 0.4% absolute for 10-100% H2
Interface Options
Power Barrier Input Voltage: 24 VDC nominal
Power Barrier Input Voltage Range: 20 VDC to 28 VDC
Intrinsically Safe Sensor Input Voltage: 10 VDC
Sensor Input Voltage Range: 5 VDC to 28 VDC
Input Power: 10 W
Analog Output: 4 mA to 20 mA
Serial Communication: RS422
Operating Conditions
Operating Humidity: 0% to 95% RH
Flow Rate: 0.1 slpm to 50 slpm
Pressure: 0 to 7 bar gauge, 0 to 100 psi gauge
Process Gas Temperature Range: -20ºC to 100ºC
Operating Temperature Range: -20ºC to 40ºC
Storage Temperature Range: -40ºC to 50ºC
Calibration Background Gas: Nitrogen
Included Accessories
Intrinsically Safe Power Barrier
4 m Power / Analog Cable
Adapter Fitting
• ½ in. MNPT thread
• ½ in. FNPT thread
• -8 SAE/MS thread size
• many other industry standards
Optional Accessories
Single Channel Intrinsically Safe Analog Output Barrier (with or without relays)
Single Channel Intrinsically Safe RS422 Serial Interface Barrier
Serial Interface Cable: 4 m (custom lengths available)
Armored Power / Analog Cable (custom lengths available)
Dimensions
Total Length: 10.3 in.
Length of Enclosure: 6.8 in.
Length of Tube: 2.9 in.
Width: 3.4 in.
Depth: 1.4 in.
©2010 H2scan Corp. All Rights Reserved